Model | ESCH48V10A-O or YNCH48V10A-O (Li-ion) | ||
---|---|---|---|
Dimensions(mm) | Long * wide * high :223*123*98(mm) | ||
Output maximum current(A) | 10 | ||
Maximum power point(W) | 592 | ||
Input voltage(VAC) | 220V±15% (Customizable) | ||
Output voltage(VDC) | Lead-acid battery:63V; VRLA:59.2V;(Customizable) | ||
Applicable battery voltage | 48 V lead-acid battery pack, (Customizable, Lithium battery optional) | ||
Maximum efficiency | 90% | ||
Output voltage regulation precision | ±1% | ||
Output current accuracy | ±1% | ||
Working temperature | -30℃~45℃ | ||
Classes of seismic measure | SAEJ1378 | ||
Cooling mode | Air blast cooling | ||
Over temperature protection | 75℃±5 | ||
Input under-voltage protection (VAC) | Under-voltage point 90V | ||
Output over-voltage protection (VDC) | 64V±1 | ||
Output over-current protection (A) | >110%*Maximum charge current | ||
Output short circuit protection | When the output is short-circuited, charger shutdown, and automatic recovery after short-circuit solved. | ||
Battery reverses protection | Charger shutdown and alarm when the wire is connected reversely, it will automatically resume after wiring correctly. |
industrial battery charger 12v, industrial battery charger 24v
- Charger integrates active power factor correction(PFC),can achieve zero pollution of power grid and avoid the impact of large current grid;
- Wide range of AC input voltage, strong adaptability;
- The module has the perfect protection function such as input over voltage, lack of input, output over current,over voltage output, output short circuit, output isolation protection, module overheating and so on;
- The full bridge phase shifted soft switch PWM the latest mixed mode control, to overcome the traditional phase shifted full bridge circuit circulation loss, working conditions of diode side faults, secondary side diodes to achieve soft recovery, the module can achieve high efficiency over a wide input voltage range and the maximum load range;
- Efficiency close to 97%, the electromagnetic interference is greatly reduced, and the volume weight is greatly reduced;
- Improved thermal design, more uniform heat distribution;
- The use of a more complete circuit board dust, moisture-proof treatment;
- (industrial battery charger 12v, industrial battery charger 24v)
- Single Chip Microcomputer (SCM) according to the lead-acid batteries tolerance current capacity, life curve, gas analysis point and other information to complete the full charge of the whole process;
- The battery having the environmental temperature compensation function to ensure that the temperature of the weather conditions, can automatically resist over-charge and under-charge.
- With pulse charging function, the battery is filled with the premise of ensuring the best life of the battery.
- With manual (charging) function
- After three paint processing and dustproof design, the reliability of the operation is improved.
- With digital display function, it can display online charging current, voltage ,and charging time.
- Charger can be used for hanging wall installation
- (industrial battery charger 12v, industrial battery charger 24v)